PKZ2
| 1 (877) 595-9616 |
Welcome to PKZ2.com |
|||||||
|
||||||||
|
Shipping Options: Same Day AIR (Sonic) Next Day Air / RED Ground / Blue
Wood Dale, IL | Englewood, FL |
|
|
||||||
|
Knowledgeable Sales Staff |
Expert Technical Support |
Representing
"WHEN YOU HAVE TO GET IT RIGHT THE 1st TIME" |
If you don't find what you are looking for on this site then click here for our complete online catalog at |
|||||
|
Buy Direct from IEC - IN STOCK |
||||||||
|
E-Mail Requests to |
Call Toll Free 1-877-595-9616 |
Fax Requests to (941) 473-0987 |
||||||
SYSTEM PKZ2
Manual Motor Protectors, Magnetic Motor Protector Combinations
and Type E Self Protected Combination Starters
UL / CSA ; IEC /EN 60 947 ; CE
![]()

|
|
Combining the PKZ2 basic module with a ZM-xx trip module forms a 3 phase thermal magnetic motor protective device incorporating adjustable bimetal trips for motor overload protection and magnetic trips to de-energize the motor circuit in case of a short circuit. |
|
|
Adding the S-PZZ2 high capacity motor contactor to the PKZ2/Zm-xx forms a combination motor starter.
|
Both PKZ2 devices are UL listed and CSA certified as HP rated motor controllers which provide motor running overload protection. In addition both PKZ2 are UL listed and CSA certified for group applications as per NEC 430-53(c) and CEC part 1, rule 28-206, This eliminates the need for individual motor branch circuit protective devices for each motor, thus greatly reducing the cost and space requirements of industrial control panels and assemblies. This means that a group of motors each protected by a PKZM/Zm..(/S) can be combined under a single branch circuit short-circuit and ground fault protective device., the maximum of which is marked on the side of each PKZ2 motor protector.
In group applications involving a number of system PKZ2 motor protectors, the maximum rating of the group branch over current device is based on the lowest backup over current rating marked on each motor protector in the group, combined with applicable NEC/CEC installation rules.
Group installations are clean and simple. The PKZ2's snap onto the din rail and Buss Bars are available to daisy chain multiple units together, eliminating power wiring all together. The buss is provided with feeder terminals and is rated at 100 amp 3 phase.
|
|
New HOT Item
|
|
|
UL 489 PKZ2/ZM-(16, 25, 32)-CB CIRCUIT BREAKERS |
||
|
Part# |
UL Interrupting ratings (AC,60)hz) 10 ka RMS Symmetrical @240Vac | Continuous Current Rating |
| PKZM2/ZM-16-CB | 16 | |
| PKZM2/ZM-25-CB | 25 | |
| PKZM2/ZM-32-8-CB | 32 | |
|
These devices are three pole thermal magnetic UL 489 inverse time molded case circuit breakers at 240 VAC. |
||
For more detailed information, see PKZ2 at KlocknerMoeller.com
Click here to go to our main online catalog
Representing
![]()
Buy Direct from IEC - IN STOCK
Call 1-866-595-9616
Internet Resources
AR, AT0, AT, ATR, DIL, DILR, DILM, DIL00M, DIL00AM, DIL0M, DIL00AM, DIL1M, DIL2M, DIL3M, DIL4M, DIL3M80, DIL4M115, DILM185, DILM250, DILM225, DILM400, DILM300, DILM580, DILM750, DILM650, DILM820, DILEM, DILER, DIUL, DILET, EASY, EASY412, EASY400, EASY600, EASY800, EMT6,EMT5, ESR, ETR4, ETR, EZ00, EZ1, FAK, FAZ, M22, N6, N10, N12, NZM6, NZM6B, NZMH6, NZM9, NZMH9, NZM10, NZM11, NZM12, NZM7, NZMH4, NZM4, OVERLOAD, OVERLOAD RELAY, PKZ2, PKZM0, PKZMO, P1, P3, SE00, SEOO, TPD, TPE, Z00, ZOO, Z1, ZEV, ZM, ZMR, ZW7, MOELLER, KLOCKNER MOELLER, MOELLER ELECTRIC, CONTACTOR, CONTACTORS, STARTERS, CIRCUIT BREAKER, CIRCUIT BREAKERS, MANUAL STARTERS, S-PKK2. SPKZ2, MANUAL MOTOR STARTERS, PS4, PS3,PLC, AUTOMATION, KM, TIMER, TIMERS, TIME DELAY, MOTOR CONTROL, MOTOR CONTROLS, zm-0.6,