PKZ2 Overview
Your authority for all PKZ2 parts, offering expert support and service with all your PKZ2 needs!


1) Manual Motor Protector
Thermal-Magnetic Motor Protector, Adjustable Thermal &
Magnetic Trips, Ambient Compensated, Phase failure
sensitive, Rated up to 42 Amps
Maximum 3 Phase HP rating: 30 @ 460/ 575 V AC
UL Listed for Group installations per NEC 430-53
CSA Certified for Group installations per CEC Part 1,
28-206, High Short Circuit Rating: Up to 65 kA/42 kA @
480/600 V AC, UL Listed, CSA Certified, in Conformity to
IEC/EN 60 947 CE Marked

2) Mounting, Wiring
Clip plate, onto which combinations of the PKZ 2/ZM-.. Motor Protector and S-PKZ 2 Magnetic contactors are mounted to form Motor Protector Combinations. Suitable for DIN rail mounting (EN 50 022). Can also be panel mounted with screws. Other Mounting/Wiring Hardware: - Adapters for direct busbar feeds in control panels.- 3 Phase Bus connectors to eliminate the need for daisychain wiring of motor protector combinations. Type: C-PKZ2

3) Corrosion Resistant Enclosures
UL/NEMA 12, IEC IP 40 and 54 Environmental ratings with cover interlocked operating handle.
Type: CI...

4) Voltage trip Modules
With Early-Make auxiliary contacts - With Drop-Off delay and Early-Make auxiliary contacts
Shunt trip module
Mounts on the side of the PKZ2/ZM Motor Protector. Type: U-PKZ 2, UHI 20-PKZ 2, UVHI-PKZ 2, A-PKZ 0

5) Remote Control Drive
Electrically turns PKZ 2/ZM Motor Protector ON and OFF, Electrically resets PKZ 2/ZM Motor Protector from Tripped position. Available in both AC and DC models. Has HAND and AUTO settings for maximum flexibility. HAND and AUTO positions are also signaled with an auxiliary contact. HAND position can be padlocked OFF. Type RS-PKZ 2 can be directly energized by a 24 V DC output from a PLC. Type: RE-PKZ 2, RS-PKZ 2

6) Magnetic Contactor Module
Magnetic Contactors
AC or 24 V DC operated versions. AC Supplied with 1
N.O./1N.C. or 2 N.O. contacts. Plugs into the load side
of the PKZ 2/ZM protector or can be separately mounted.
Can be equipped with 4th (Neutral) Pole.
Rated 20 kW @ 400/415 V AC. IEC 60 947-4-1 rated for
Type 1 co-ordination. CE Marked. For IEC/EN
applications. Type: SE1A/...-PKZ 2, SE1A-G-...-PKZ2

7) High Capacity Magnetic
Contactor Module
Magnetic Contactors
Internal current limitation feature to increase short
circuit current rating and self-protection
characteristics. AC or 24 V DC operated versions.
AC Supplied with 1 N.O./1N.C. or 2 N.O. contacts.
Plugs into the load side of the PKZ 2/ZM protector to
create PKZ 2/ZM-.../S Magnetic Motor Protector
combination. In association with PKZ 2/ZM:
Maximum 3 Phase HP rating: 30 @ 460/ 575 V AC
UL Listed for Group installations per NEC 430-53
CSA Certified for Group installations per CEC Part 1,
28-206 High Short Circuit Rating: Up to 65 kA/42 kA @
480/600 V AC Rated 20 kW @ 400/415 V AC.
IEC 60 947-4-1 rated for Type 2 co-ordination. UL
Listed, CSA Certified, in conformity with IEC/EN 60 947
CE Marked

8) Current Limiter Module

9) Door/Cover Mounted Handle
Black, or Red/Yellow for E-Stop function Type: (R)H-PKZ 2

10) Auxiliary Contact Modules
Auxiliary
Contact Modules
Signals ON/OFF status of PKZ 2/ZM Motor Protector and
PKZ 2/ZM-.../S Motor Protector + Contactor combination.
Trip indicating contacts which differentiate between
overload and short circuit tripping. Type: NHI-...-PKZ
2, AGM-...-PKZ 2
Special Offers

See
how the PKZ2 Systems works together for optimal performance and
protection.
More >

View
the technical paper for PKZ2 Systems for optimum motor and
system protection More >
Ready to Order?
Call Toll Free:
1-877-595-9616 for Superior Tech Support, Service
and Same Day Shipping!
![]()