PKZ2 Shunt Trips and Undervoltage
Releases
Your authority for all PKZ2 Shunt Trips and Undervoltage Releases, offering expert support and service with all your PKZ2 needs!
Shunt trips are available in three models which cover a wide range of AC and DC voltages. They can be used in combination with R(E)(S)-PKZ2 remote control drives.
| Article # | Description | Trips the PKZ2 when external voltage is applied |
|
|---|---|---|---|
| A-PKZ2-A | 063967 | Shunt Trip Module![]() |
Specify Voltage and AC or DC 24 V DC 48 V DC 60 V DC 24 V 50 Hz 48 V 50 Hz 24 V 60 Hz 48 V 60 Hz |
| A-PKZ2-B | 063964 | Specify Voltage and AC or DC 110 V DC 125 V DC 250 V DC 110 V 50 Hz 127 V 50 Hz 220 V 50 Hz 230 V 50 HZ 240 V 50 Hz 110 V 60 Hz 120 V 60 Hz 208 V 60 Hz 220 V 60 Hz 240 V 60 Hz |
|
| A-PKZ2-C | 063930 | Specify Voltage and AC or DC 380 V 50 Hz 400 V 50 Hz 415 V 50 Hz 440 V 50 Hz, 500 V 50 Hz 480 V 60 Hz 600 V 60 Hz |
|
| Can be combined with the motor protector to accomplish Emergency-stop circuitry per IEC/EN 60 204. Can be used in combination with R(E)(S)-PKZ2 remote control drives | |||
| Article # | Description | Voltage | |
| U-PKZ2(24V50HZ) | 055085 | Trips the PKZ2 when external voltage is removed |
24V50HZ |
| U-PKZ2(220V50HZ,240V60HZ) | 065685 | 220V50HZ, 240V60HZ |
|
| U-PKZ2(230V50HZ,240V60HZ) | 065766 | 230V50HZ, 240V60HZ |
|
| U-PKZ2(400V50HZ,440V60HZ) | 065767 | 400V50HZ, 440V60HZ |
|
| U-PKZ2(24VDC) | 014463 | For DC | 24VDC |
| U-PKZ2(48VDC) | 028701 | Trips the PKZ2 when external voltage is removed |
48VDC |
| U-HI20-PKZ2(*V50HZ) | 907537 | Trips the PKZ2 when external voltage is removed. Includes a set of early make contacts. In the trip position, both contacts will be closed. The trip coil can be energized early by jumpering from the contact, however in this move it will not be possible to combine it with the R(E)(S)-PKZ2 remote control drives. Under voltage Trip Module (for AC) |
*V50HZ |
| U-HI20-PKZ2(110V50HZ,120V60HZ) | 063655 | 110V50HZ,120V60HZ | |
| U-HI20-PKZ2(*V60HZ) | 907538 | *V60HZ | |
| U-HI20-PKZ2(220V50HZ,240V60HZ) | 063656 | 220V50HZ,240V60HZ | |
| U-HI20-PKZ2(230V50HZ,240V60HZ) | 065768 | 230V50HZ,240V60HZ | |
| U-HI20-PKZ2(24V50/60HZ) | 063659 | 24V50/60HZ | |
| U-HI20-PKZ2(24V50HZ) | 063649 | 24V50HZ) | |
| Has a built in time delay to prevent tripping due to momentary power losses of 200 ms or less. In the trip position, both contacts will be closed. Can be used in combination with the R(E)(S)-PKZ2 remote control drives. | |||
| UVHI-PKZ2(120V60HZ) | 063664 | Drop-off delayed (200ms) For AC with auxiliary contact |
120V60HZ |
Special Offers

See
how the PKZ2 Systems works together for optimal performance and
protection.
More >

View
the technical paper for PKZ2 Systems for optimum motor and
system protection More >