3 phase thermal magnetic motor protective devices

TYPE

Article Number

Description Amps Amps Hp @ 230 Hp @ 460
PKZ2

Basic Module

   No Trip Module installed

Adjustable thermal range set to motor FLC Adjustable trip setting current of magnetic trips 15 30

Install one of the following trip modules

ZM-0.6

Trip Module

0.4-0.6 5 - 8 - -
ZM-1 Trip Module 0.6-1 8 - 14 - 1/2
ZM-1.6 Trip Module 1-1.6 14 - 22 - 3/4
ZM-2.4 Trip Module 1.6-2.4 20 - 35 1/2 1
ZM-4 Trip Module 2.4-4 35 - 55 1 2
ZM-6 Trip Module 4-6 50 - 80 1 1/2 3
ZM-10 Trip Module 6-10 80 - 140 3 5
ZM-16 Trip Module 10-16  130 - 220 5 10
ZM-25 Trip Module 16-25 200 - 350 7 1/2 20
ZM-32 Trip Module 25-32 275 - 425 10 20
ZM-40 Trip Module 32-40 350 - 500 15 30

Bolt on Integrated Contactor

S-PKZ2 AC Coil Contactor (Specify Voltage) -   15 30
S-G-PKZ2 DC Coil Contactor (Specify Voltage) -   15 30

 

Manual Motor Protectors with Trip Module

TYPE

Article Number

Description Amps Amps Hp @ 230 Hp @ 460
PKZ2

Basic Module

 with Trip Module Installed

Adjustable thermal range set to motor FLC Adjustable trip setting current of magnetic trips 15 30

The PKZ2-ZM-... is a 3-phase thermal magnetic motor protective device incorporating adjustable bimetal trips for motor overload protection and magnetic trips to de-energize the motor circuit in case of a short circuit.

 

UL listed and CSA certified as HP rated motor controllers which provide motor running overload protection.  In addition, they are UL listed and CSA certified for group applications as per NEC 430-53(c) and CEC part 1, rule 28-206.  This eliminates the need for individual motor branch circuit over current protective devices for each motor, thus greatly reducing the cost and space requirements of industrial control panels and assemblies.  This manes that a group of motors, each protected and controlled by PKZ2/SM...(/s) can be combined under a single branch circuit short circuit and ground fault protective device, the maximum rating of which is marked on each PKZ2 motor protector.

 

In group installations involving a number of System PKZ2 motor protectors, the maximum rating of the group branch circuit over current protective device is based on the lowest backup over current rating marked on each motor protector in the group, combines with applicable NEC/CEC installation rules.

PKZ2/ZM-0.6

021859

Includes Trip Module

0.4 - 0.6 5 - 8 - -

PKZ2/ZM-1

026605

Includes Trip Module

0.6 - 1 8 - 14 - 1/2

PKZ2/ZM-1.6

028978

Includes Trip Module

1 - 1.6 14 - 22 - 3/4

PKZ2/ZM-2.4

031351

Includes Trip Module

1.6 - 2.4 20 - 35 1/2 1

PKZ2/ZM-4

033724

Includes Trip Module

2.4 - 4 35 - 55 1 2

PKZ2/ZM-6

036097

Includes Trip Module

4 - 6 50 - 80 1 1/2 3

PKZ2/ZM-10

038470

Includes Trip Module

6 - 10 80 - 140 3 5

PKZ2/ZM-16

040843

Includes Trip Module

10 - 16  130 - 220 5 10

PKZ2/ZM-25

043216

Includes Trip Module

16 - 25 200 - 350 7 1/2 20

PKZ2/ZM-32

045589

Includes Trip Module

25 - 32 275 - 425 10 20

PKZ2/ZM-40

047962

Includes Trip Module

32 - 40 350 - 500 15 30

 

Magnetic Motor Protector Combinations with High Capacity Contactor

TYPE

Article Number

Description Amps Amps Hp @ 230 Hp @ 460
PKZ2

Basic Module with Trip Module Installed

Adjustable thermal range set to motor FLC Adjustable trip setting current of magnetic trips 15 30

The PKZ2-ZM-../S is a combination of the PKZ2/ZM-... manual motor protector and the S-PKZ2 high capacity magnetic contactor.

 

UL listed and CSA certified as HP rated motor controllers which provide motor running overload protection.  In addition, they are UL listed and CSA certified for group applications as per NEC 430-53(c) and CEC part 1, rule 28-206.  This eliminates the need for individual motor branch circuit over current protective devices for each motor, thus greatly reducing the cost and space requirements of industrial control panels and assemblies.  This manes that a group of motors, each protected and controlled by PKZ2/SM...(/s) can be combined under a single branch circuit short circuit and ground fault protective device, the maximum rating of which is marked on each PKZ2 motor protector.

 

In group installations involving a number of System PKZ2 motor protectors, the maximum rating of the group branch circuit over current protective device is based on the lowest backup over current rating marked on each motor protector in the group, combines with applicable NEC/CEC installation rules.

PKZ2/ZM-0.6/S

(120V60HZ)

063460

Includes High Capacity Contactor 0.4 - 0.6 5 - 8 - -

PKZ2/ZM-1/S

(120V60HZ)

063470

Includes High Capacity Contactor 0.6 - 1 8 - 14 - 1/2

PKZ2/ZM-1.6/S

(120V60HZ)

063480

Includes High Capacity Contactor 1 - 1.6 14 - 22 - 3/4

PKZ2/ZM-2.4/S

(120V60HZ)

063490

Includes High Capacity Contactor 1.6 - 2.4 20 - 35 1/2 1

PKZ2/ZM-4/S

(120V60HZ)

063500

Includes High Capacity Contactor 2.4 - 4 35 - 55 1 2

PKZ2/ZM-6/S

(120V60HZ)

063510

Includes High Capacity Contactor 4 - 6 50 - 80 1 1/2 3

PKZ2/ZM-10/S

(120V60HZ)

063520

Includes High Capacity Contactor 6 - 10 80 - 140 3 5

PKZ2/ZM-16/S

(120V60HZ)

063530

Includes High Capacity Contactor 10 - 16  130 - 220 5 10

PKZ2/ZM-25/S

(120V60HZ)

063540

Includes High Capacity Contactor 16 - 27 200 - 350 7 1/2 20

PKZ2/ZM-32/S

(120V60HZ)

063550

Includes High Capacity Contactor

24 - 32 275 - 425 10 20

PKZ2/ZM-40/S

(120V60HZ)

063560

Includes High Capacity Contactor 32 - 42 350 - 500 15 30

 

Motor Protectors without Trip Module

The PKZ 2 manual motor protector and PKZ 2/S... motor protector combination without plug-in trip modules make up one frame size rated for a maximum continuous motor load current of 42 Amps.  These devices can be stocked, or mounted and wired in a panel, without prior knowledge of motor Hp ratings.  Motor overload and over current protection is provided by the plug-in motor protective trip modules which are inserted into the slots below the handle (between the disconnect and contactor portions) and enable the motor protector to cover to a motor range from fractional Hp to 30 Hp at 460/575VAC.

 

Once motor loads are determined, selection of the appropriate plug-in protective trip module can take place.  Exchanging trip modules is easy and does not require any removal of wiring or cable.  Removal of the trip modules provides an additional safety benefit by creating an open circuit path to the motor.  This still allows the performance of routine motor maintenance tasks and circuit function checks but effectively rules out any inadvertent energization of the motor.

TYPE

Article Number

Amps
PKZ2 Rated uninterrupted current
Basic Device

PKZ2

026606

42

PKZ2 Basic Unit with S-PKZ 2 High Capacity Contact Mounted

(1 N.O., 1 N.C.) Supplied on C-PKZ2 clip plate

PKZ2/S (120V60HZ)

063570

42

 

Plug In Motor Protective Trip Modules

TYPE

Article Number

UL/CSA max. 3 phase HP rating at: Adjustable thermal range (set to motor FLC) Setting range of adjustable magnetic trips
PKZ2 230 V 460 V Amps Amps

with overload trip

Standard trip modules are inserted on the load side of the motor protector disconnect handle.  In case of overload or short circuit, the tip module will cause the motor protector switch mechanism to open and disconnect power to the load.

FEATURES:

§ Adjustable and thermal magnetic trips set in accordance with the motor FLC.

§ Tamper proof lids that cover thermal and magnetic settings when the device is on

§ Ambient compensation

§ Phase failure sensitivity

§ Coding accessory to insure insertion of correct module for the motor rating

ZM-0.6-PKZ2

024232

In this range, select motor protector in accordance with the motor name plate FLC   0.4 - 0.6 5 - 8

ZM-1-PKZ2

028979

1/2 0.6 - 1 8 - 14

ZM-1.6-PKZ2

031352

3/4 1 - 1.6 14 - 22

ZM-2.4-PKZ2

033725

1/2 1 1.6 - 2.4 20 - 35

ZM-4-PKZ2

036098

1 2 2.4 - 4 35 - 55

ZM-6-PKZ2

038471

1 1/2 3 4 - 6 50 - 80

ZM-10-PKZ2

040844

3 5 6 - 10 80 - 140

ZM-16-PKZ2

043217

5 10 10 - 16  130 - 220

ZM-25-PKZ2

045590

7 1/2 20 16 - 27 200 - 350

ZM-32-PKZ2

047963

10 20 24 - 32 275 - 425

ZM-40-PKZ2

050336

15 30 32 - 42 350 - 500

with overload relay function, with Hand/Auto position

Trip modules with overload relay function are inserted in the load side of the motor protector disconnect handle.  Similar to the operation of an overload relay, the ZMR uses a set of auxiliary contacts to de-energize a contactor coil circuit and signal an overload condition.  A short circuit will trip open the motor protector like the standard ZM trip module.  The ZMR is also supplied with a HAND/AUTO reset feature.  It cannot be combined with U/A voltage trips or RE/RS remote control drives.

FEATURES:

§ Adjustable and thermal magnetic trips set in accordance with the motor FLC.

§ Tamper proof lids that cover thermal and magnetic settings when the device is on

§ Ambient compensation

§ Phase failure sensitivity

§ Coding accessory to insure insertion of correct module for the motor rating

ZMR-0.6-PKZ2

033943

In this range, select motor protector in accordance with the motor name plate FLC   0.4 - 0.6 5 - 8

ZMR-1-PKZ2

033950

1/2 0.6 - 1 8 - 14

ZMR-1.6-PKZ2

033952

3/4 1 - 1.6 14 - 22

ZMR-2.4-PKZ2

033955

1/2 1 1.6 - 2.4 20 - 35

ZMR-4-PKZ2

033957

1 2 2.4 - 4 35 - 55

ZMR-6-PKZ2

033966

1 1/2 3 4 - 6 50 - 80

ZMR-10-PKZ2

033967

3 5 6 - 10 80 - 140

ZMR-16-PKZ2

033968

5 10 10 - 16  130 - 220

ZMR-25-PKZ2

033969

7 1/2 20 16 - 27 200 - 350

ZMR-32-PKZ2

033973

10 20 24 - 32 275 - 425

ZMR-40-PKZ2

033975

15 30 32 - 42 350 - 500

 

Self Protected Combination Starters - FVNR, FVR, Open Type, UL/CSA Type E

TYPE

UL/CSA max. 3 phase HP rating at:
PKZ2 230 V 460 V

Full Voltage, Non-reversing Starter

without trip module

Ready to be mounted and wired in its own enclosure.  The HP values shown are the maximum allowable and are dependant on the trip module chosen.  Trip modules shown in chart below can be selected later according to desired motor HP and FLC and plugged into the disconnect complete the starter.  Trip modules can be field installed for maximum flexibility.

PKZ2/S-SP

(Specify coil voltage and frequency)

033975

15 30

Full Voltage, Reversing Starter

without trip module

Supplied with factory mounted and wired disconnect and mechanically interlocked contactors.  The HP values shown below are the maximum allowable and are dependant on the trip module chosen.  Trip modules in shown in chart below can be selected later according to desired motor HP and FLC and plugged into the disconnect complete the starter.  Trip modules can be field installed for maximum flexibility.

PKZ2/S-SP-FVR

(Specify coil voltage and frequency)

15 30

 

Trip Modules

with overload trip

Standard trip modules are inserted on the load side of the motor protector disconnect handle.  In case of overload or short circuit, the tip module will cause the motor protector switch mechanism to open and disconnect power to the load.

FEATURES:

§ Adjustable and thermal magnetic trips set in accordance with the motor FLC.

§ Tamper proof lids that cover thermal and magnetic settings when the device is on

§ Ambient compensation

§ Phase failure sensitivity

§ Coding accessory to insure insertion of correct module for the motor rating

ZM-0.6-PKZ2

024232

In this range, select motor protector in accordance with the motor name plate FLC   0.4 - 0.6 5 - 8

ZM-1-PKZ2

028979

1/2 0.6 - 1 8 - 14

ZM-1.6-PKZ2

031352

3/4 1 - 1.6 14 - 22

ZM-2.4-PKZ2

033725

1/2 1 1.6 - 2.4 20 - 35

ZM-4-PKZ2

036098

1 2 2.4 - 4 35 - 55

ZM-6-PKZ2

038471

1 1/2 3 4 - 6 50 - 80

ZM-10-PKZ2

040844

3 5 6 - 10 80 - 140

ZM-16-PKZ2

043217

5 10 10 - 16  130 - 220

ZM-25-PKZ2

045590

7 1/2 20 16 - 27 200 - 350

ZM-32-PKZ2

047963

10 20 24 - 32 275 - 425

ZM-40-PKZ2

050336

15 30 32 - 42 350 - 500

with overload relay function, with Hand/Auto position

Trip modules with overload relay function are inserted in the load side of the motor protector disconnect handle.  Similar to the operation of an overload relay, the ZMR uses a set of auxiliary contacts to de-energize a contactor coil circuit and signal an overload condition.  A short circuit will trip open the motor protector like the standard ZM trip module.  The ZMR is also supplied with a HAND/AUTO reset feature.  It cannot be combined with U/A voltage trips or RE/RS remote control drives.

FEATURES:

§ Adjustable and thermal magnetic trips set in accordance with the motor FLC.

§ Tamper proof lids that cover thermal and magnetic settings when the device is on

§ Ambient compensation

§ Phase failure sensitivity

§ Coding accessory to insure insertion of correct module for the motor rating

ZMR-0.6-PKZ2

033943

In this range, select the devices in accordance with the motor FLC   0.4 - 0.6 5 - 8

ZMR-1-PKZ2

033950

1/2 0.6 - 1 8 - 14

ZMR-1.6-PKZ2

033952

3/4 1 - 1.6 14 - 22

ZMR-2.4-PKZ2

033955

1/2 1 1.6 - 2.4 20 - 35

ZMR-4-PKZ2

033957

1 2 2.4 - 4 35 - 55

ZMR-6-PKZ2

033966

1 1/2 3 4 - 6 50 - 80

ZMR-10-PKZ2

033967

3 5 6 - 10 80 - 140

ZMR-16-PKZ2

033968

5 10 10 - 16  130 - 220

ZMR-25-PKZ2

033969

7 1/2 20 16 - 27 200 - 350

ZMR-32-PKZ2

033973

10 20 24 - 32 275 - 425

ZMR-40-PKZ2

033975

15 30 32 - 42 350 - 500

 

Combination Starters - FVNR, UL/CSA Type E

STANDARD FEATURES:

§ UL listed, CSA certified, self-protected combination motor controller.  UL 508 / CSA 22.2, No. 14 Type E.

§ Factory mounted and labeled contactor and disconnect portion rates max 42A, 30 HP at 460V; max 27A HP at 575V.

§ No backup over current protection required up to its full interrupting rating.

§ Continuity of service (protects itself against damage under fault conditions).

§ Plug in trip module, which creates an open circuit path to the motor when removed.  For additional safety.

§ Adjustable thermal and magnetic trips; built in phase loss differential trip.

§ Built in 1normally open and 1 normally closed auxiliary contacts in the contactor portions.  2 normally open are also available.

§ Electrical life: 1 million operations, AC-3 (30/25 HP at 460/575V).

§ Adapter plate for rail or panel mounting.

§ Control circuit transformer tap-off terminals on load side of disconnect.

§ Allows mounting of accessories such as voltage trips, standard and trip indicating auxiliary contacts.

§ Enclosed starters provided with door interlocking handle.

§ In the event of an overload condition, the normally closed contactor in the ZMR-...-PKZ2 trip module opens the contactor coil circuit and the normally open contact may be used to remotely signal an overload condition.  On a short circuit, the main disconnect switch opens.

Type

UL/CSA max. 3 phase HP rating at:

Adjustable thermal range (set to motor FLC)

Setting range of adjustable magnetic trips

PKZ2

230 V HP

430 V HP

Amps

Amps

With ZM trip module

PKZ2/ZM-0.6/S-SP

(Specify coil voltage and frequency)

In this range, select the devices in accordance with the motor FLC

  0.4 - 0.6 5 - 8

PKZ2/ZM-1/S-SP

(Specify coil voltage and frequency)

1/2 0.6 - 1 8 - 14

PKZ2/ZM-1.6/S-SP

(Specify coil voltage and frequency)

1/3

3/4 1 - 1.6 14 - 22

PKZ2/ZM-2.4/S-SP

(Specify coil voltage and frequency)

1/2 1 1.6 - 2.4 20 - 35

PKZ2/ZM-4/S-SP

(Specify coil voltage and frequency)

1 2 2.4 - 4 35 - 55

PKZ2/ZM-6/S-SP

(Specify coil voltage and frequency)

1 1/2 3 4 - 6 50 - 80

PKZ2/ZM-10/S-SP

(Specify coil voltage and frequency)

3 5 6 - 10 80 - 140

PKZ2/ZM-16/S-SP

(Specify coil voltage and frequency)

5 10 10 - 16  130 - 220

PKZ2/ZM-25/S-SP

(Specify coil voltage and frequency)

7 1/2 20 16 - 27 200 - 350

PKZ2/ZM-32/S-SP

(Specify coil voltage and frequency)

10 20 24 - 32 275 - 425

PKZ2/ZM-40/S-SP

(Specify coil voltage and frequency)

15 30 32 - 42 350 - 500

With ZMR trip module

PKZ2/ZMR-0.6/S-SP

(Specify coil voltage and frequency)

In this range, select the devices in accordance with the motor FLC

  0.4 - 0.6 5 - 8

PKZ2/ZMR-1/S-SP

(Specify coil voltage and frequency)

1/2 0.6 - 1 8 - 14

PKZ2/ZMR-1.6/S-SP

(Specify coil voltage and frequency)

1/3

3/4 1 - 1.6 14 - 22

PKZ2/ZMR-2.4/S-SP

(Specify coil voltage and frequency)

1/2 1 1.6 - 2.4 20 - 35

PKZ2/ZMR-4/S-SP

(Specify coil voltage and frequency)

1 2 2.4 - 4 35 - 55

PKZ2/ZMR-6/S-SP

(Specify coil voltage and frequency)

1 1/2 3 4 - 6 50 - 80

PKZ2/ZMR-10/S-SP

(Specify coil voltage and frequency)

3 5 6 - 10 80 - 140

PKZ2/ZMR-16/S-SP

(Specify coil voltage and frequency)

5 10 10 - 16  130 - 220

PKZ2/ZMR-25/S-SP

(Specify coil voltage and frequency)

7 1/2 20 16 - 27 200 - 350

PKZ2/ZMR-32/S-SP

(Specify coil voltage and frequency)

10 20 24 - 32 275 - 425

PKZ2/ZMR-40/S-SP

(Specify coil voltage and frequency)

15 30 32 - 42 350 - 500

 

Auxiliary Contacts

Part #

Description Normally Open Normally Closed
Side mounted auxiliary contacts operate in conjunction with the motor protector contacts.  Can be mounted to a motor protector or motor protector combination.  Can be combines with AGM trip indicating contacts.

NHI11-PKZ2

090677

Side Mount Aux Contact for PKZ2

On PKZ2

1

normally open

1

normally closed

NHI22-PKZ2

097796

Side Mount Aux Contact for PKZ2

On PKZ2

2

normally open

2

normally closed

Type NHI-11S-PKZ2 has a set of contacts operated by the motor protector, the other set by the contactor.  Can be mounted to motor protector combination.  Can be combined with AGM trip indicating contacts.

NHI11S-PKZ2

007623

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

1

normally open

1

normally closed

On Contactor

-

 

-

 

NHI11S/EZ-PKZ-2

090305

Fits to the side of separately mounted contactors

On PKZ2

1

normally open

1

normally open

On Contactor

1

normally open

1

normally open

NHI22S-PKZ2

000504

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

2

normally open

2

normally closed

On Contactor

-

 

-

 

NHI12-11S-PKZ2

009996

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

1

normally open

1

normally closed

On Contactor

1

normally open

1

normally closed

Axilliary contact inserts -

Mounts in the top portion of the contactor

HI11-S-PKZ2

033936

Replacement aux contacts for the built in ones on the contactor On Contactor

1

normally open

1

normally closed

HI20-S-PKZ2

033935

2

normally open

-

 

Trip Indicating Contacts, Trip Indicators and Current Limiters
AGM...-PKZ2 provides trip differentiating contacts and is supplied with K-AGM-PKZ2 red short-circuit indicator.  Cab be mounted to motor protector combinations.  Can be combined with NHI... or NHI...S.

AGM2-11-PKZ2

017115

Trip Indicating Contacts for PKZ2

Transfers under any trip condition

Transfers only on short circuit trip

1 normally open

1 normally closed

1 normally open

1 normally closed

Provides a visual signal of a short circuit trip condition via a resetable red flag indicator.  Differentiated trip signaling possible in conjunction with handle position.

K-AGM-PKZ2

021861

Short circuit indicator - -

Fuseless, current limiting set of contacts housed in a module.  Increases short circuit current rating of PKZ2/ZM up to 100kA/500V AC in IEC group applications.  Not UL/CSA.

Can be mounted to motor protector or mounted separately on EZ base.

CL-PKZ2

076439

Current Limiter Max. rated operational voltage Ue = 690 V

 

Shunt Trips and Undervoltage Trips
Shunt trips are available in three models which cover a wide range of AC and DC voltages.  They can be used in combination with R(E)(S)-PKZ2 remote control drives.

A-PKZ2-A

063967

Shunt Trip Module

Trips the PKZ2 when external voltage is applied

 

         Specify voltage and (Ac or DC )       

24 V DC            48 V DC              60 V DC

24 V 50 Hz        48 V 50 Hz

24 V 60 Hz        48 V 60 Hz

A-PKZ2-B

063964

Shunt Trip Module

Trips the PKZ2 when external voltage is applied

 

           Specify voltage and (Ac or DC )             

110 V DC            125 V DC             250 V DC

110 V 50 Hz        127 V 50 Hz         220 V 50 Hz

230 V 50 Hz        240 V 50 Hz

110 V 60 Hz        120 V 60 Hz         208 V 60 Hz

220 V 60 Hz        240 V 60 Hz

A-PKZ2-C

063930

Shunt Trip Module

Trips the PKZ2 when external voltage is applied

 

           Specify voltage and (Ac or DC )              

380 V 50 Hz        400 V 50 Hz         415 V 50 Hz

440 V 50 Hz        500 V 50 Hz        

480 V 60 Hz        600 V 60 Hz

 

Can be combined with the motor protector to accomplish Emergency-stop circuitry per IEC/EN 60 204.  Can be used in combination  with R(E)(S)-PKZ2 remote control drives.

U-PKZ2 (120V60HZ)

065686

Under voltage Trip Module (for AC)

Trips the PKZ2 when external voltage is removed

U-PKZ2 (24 V DC)

014463

Under voltage Trip Module (for DC)

Trips the PKZ2 when external voltage is removed

U-HI20-PKZ2

063655

Under voltage Trip Module (for AC)

Trips the PKZ2 when external voltage is removed.

Includes a set of early make contacts.  In the trip position, both contacts will be closed.  The trip coil can be energized early by jumpering from the contact, however in this move it will not be possible to combine it with the R(E)(S)-PKZ2 remote control drives.

Has a built in time delay to prevent tripping due to momentary power losses of 200 ms or less.  In the trip position, both contacts will be closed.  Can be used in combination with the R(E)(S)-PKZ2 remote control drives.

UVHI-PKZ2(120V60HZ)

063664

Drop-off delayed (200ms) For AC with auxiliary contact

 

Remote Control Drives

Remote control drives can be used with both the motor protector and motor protector combination.  They are used to electrically

 operate the motor protector.  They can be switched off at the device and thumb-grip handle can be padlocked using a 6 mm padlock.  Suitable for use with either AC or DC voltages.  Can be combined with undervoltage trips and shunt trips.  Always used standard auxiliary contact Type NHI when using remote control drives to electrically signal the open or closed status of the motor protector.  Remote control drives cannot be used in conjunctions with the (R)H-PKZ2 door interlock handle.

Mounting is possible in both ON and OFF positions of the motor protector.  An internal electronic interlock always sets OFF as the default setting.

The thumb grip handle has 2 positions: HAND and AUTO.  In HAND: the drive displays the color GREEN and blocks any remote electrical actuation.  The internal signaling contact 33/34 is open.  In AUTO: the drive displays the color RED, indicating that remote electrical actuation is possible.  The internal signaling contact 33/34 is closed.

RE-PKZ2(110-120V50/60HZ,DC)

063673

Used to electrically operate the PKZ2. Line voltage control.

OFF and RESET separate.

Line and control feeds have the same potential.  The control section can be energized by a single impulse of 15 ms duration, or by a maintained contact.  Upon energizing, the line connection draws its power requirement (700 VA/W for a duration ms 30 ms) directly from the line.

Control section can also be actuated via auxiliary contacts from various Moeller Electric components: NHI, AGM, ETR4-VS3, EK... and dry output contacts from PLCs with no RC filter type surge suppression.

RS-PKZ2 (24V50/60HZ,DC)

063670

Used to electrically  operate the PKZ2. Control voltage from external source such as a PLC.

OFF equals RESET.

RS-PKZ2 (110-120V50/60HZ,DC)

063685

Used to electrically  operate the PKZ2.

Line control sections are galvanically separated.  The control section is energized solely from a 24V DC source by a single impulse or by a maintained contact.  Suitable for energizing directly from an electronic PLC output.

Upon energizing, the line connection draws its power requirement (700 VA/W for a duration for 30 ms) directly from the line.

RS-PKZ2 (24V50/60HZ,DDC)

063682

Used to electrically  operate the PKZ2.

 

Magnetic Contactors and Surge Suppressors

Part #

Amps Amps Number of contacts
PKZ2 230 V 460 V Normally Open Normally Closed
 

NHI11-PKZ2

090677

 

On PKZ2

 

1

normally open

1

normally closed

NHI22-PKZ2

097796

 

On PKZ2

2

normally open

2

normally closed

Type NHI-11S-PKZ2 has a set of contacts operated by the motor protector, the other set by the contactor.  Can be mounted to motor protector combination.  Can be combined with AGM trip indicating contacts.

NHI11S-PKZ2

007623

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

1

normally open

1

normally closed

On Contactor

-

 

-

 

NHI11S/EZ-PKZ-2

090305

Fits to the side of separately mounted contactors

On PKZ2