STANDARD FEATURES:
  • UL listed, CSA certified, self-protected combination motor controller. UL 508 / CSA 22.2, No. 14 Type E.
  • Factory mounted and labeled contactor and disconnect portion rates max 42A, 30 HP at 460V; max 27A HP at 575V.
  • No backup over current protection required up to its full interrupting rating.
  • Continuity of service (protects itself against damage under fault conditions).
  • Plug in trip module, which creates an open circuit path to the motor when removed. For additional safety.
  • Adjustable thermal and magnetic trips; built in phase loss differential trip.
  • Built in 1normally open and 1 normally closed auxiliary contacts in the contactor portions. 2 normally open are also available.
  • Electrical life: 1 million operations, AC-3 (30/25 HP at 460/575V).
  • Adapter plate for rail or panel mounting.
  • Control circuit transformer tap-off terminals on load side of disconnect.
  • Allows mounting of accessories such as voltage trips, standard and trip indicating auxiliary contacts.
  • Enclosed starters provided with door interlocking handle.
  • In the event of an overload condition, the normally closed contactor in the ZMR-...-PKZ2 trip module opens the contactor coil circuit and the normally open contact may be used to remotely signal an overload condition. On a short circuit, the main disconnect switch opens.


PKZ2 Combination Starters - FVNR, UL/CSA Type E

With ZM Trip Module
(Specify coil voltage and frequency)

  Article # UL/CSA max. 3 Phase HP rating at: Adjustable thermal range (set to motor FLC) Setting range of adjustable magnetic trips
230 V 460 V
PKZ2/ZM-0.6/S-SP   See Note* See Note* 0.4 - 0.6 5 - 8
PKZ2/ZM-1/S-SP   See Note* 1/2 0.6 - 1 8 - 14
PKZ2/ZM-1.6/S-SP   1/3 3/4 1 - 1.6 14 - 22
PKZ2/ZM-2.4/S-SP   1/2 1 1.6 - 2.4 20 - 35
PKZ2/ZM-4/S-SP   1 2 2.4 - 4 35 - 55
PKZ2/ZM-6/S-SP   1 1/2 3 4 - 6 50 - 80
PKZ2/ZM-10/S-SP   3 5 6 - 10 80 - 140
PKZ2/ZM-16/S-SP   5 10 10 - 16 130 - 220
PKZ2/ZM-25/S-SP   7 1/2 20 16 - 27 200 - 350
PKZ2/ZM-32/S-SP   10 20 24 - 32 275 - 425
PKZ2/ZM-40/S-SP   15 30 32 - 42 350 - 500
*Note: In this range, select motor protector in accordance with the motor name plate FLC

 

With ZMR Trip Module
(Specify coil voltage and frequency)

PKZ2/ZMR-0.6/S-SP   See Note* See Note* 0.4 - 0.6 5 - 8
PKZ2/ZMR-1/S-SP   See Note* 1/2 0.6 - 1 8 - 14
PKZ2/ZMR-1.6/S-SP   1/3 3/4 1 - 1.6 14 - 22
PKZ2/ZMR-2.4/S-SP   1/2 1 1.6 - 2.4 20 - 35
PKZ2/ZMR-4/S-SP   1 2 2.4 - 4 35 - 55
PKZ2/ZMR-6/S-SP   1 1/2 3 4 - 6 50 - 80
PKZ2/ZMR-10/S-SP   3 5 6 - 10 80 - 140
PKZ2/ZMR-16/S-SP   5 10 10 - 16 130 - 220
PKZ2/ZMR-25/S-SP   7 1/2 20 16 - 27 200 - 350
PKZ2/ZMR-32/S-SP   10 20 24 - 32 275 - 425
PKZ2/ZMR-40/S-SP   15 30 32 - 42 350 - 500
*Note: In this range, select motor protector in accordance with the motor name plate FLC