Special Offers

PKZ2 Systems
See how the PKZ2 Systems works together for optimal performance and protection.
More >


PKZ2 Technical Paper
View the technical paper for PKZ2 Systems for optimum motor and system protection More >

Ready to Order?

Call Toll Free: 1-866-595-9616 for Superior Tech Support, Service
and Same Day Shipping!
UPS Shipping for your PKZ2 Parts!

Navigation

PKZ2 Remote Control Drives

Your authority for PKZ2 Remote Control Drives offering expert support and service with all your PKZ2 needs!


Remote control drives can be used with both the motor protector and motor protector combination. They are used to electrically operate the motor protector. They can be switched off at the device and thumb-grip handle can be padlocked using a 6 mm padlock. Suitable for use with either AC or DC voltages. Can be combined with undervoltage trips and shunt trips. Always used standard auxiliary contact Type NHI when using remote control drives to electrically signal the open or closed status of the motor protector. Remote control drives cannot be used in conjunctions with the (R)H-PKZ2 door interlock handle. Mounting is possible in both ON and OFF positions of the motor protector. An internal electronic interlock always sets OFF as the default setting. The thumb grip handle has 2 positions: HAND and AUTO. In HAND: the drive displays the color GREEN and blocks any remote electrical actuation. The internal signaling contact 33/34 is open. In AUTO: the drive displays the color RED, indicating that remote electrical actuation is possible. The internal signaling contact 33/34 is closed.

  Article # Adjustable thermal range (set to motor FLC) Setting range of adjustable magnetic trips
RE-PKZ2(110-120V50/60HZ,DC) 063673 Used to electrically operate the PKZ2. Line voltage control.

OFF and RESET separate.
Line and control feeds have the same potential. The control section can be energized by a single impulse of 15 ms duration, or by a maintained contact. Upon energizing, the line connection draws its power requirement (700 VA/W for a duration ms 30 ms) directly from the line.
Control section can also be actuated via auxiliary contacts from various Moeller Electric components: NHI, AGM, ETR4-VS3, EK... and dry output contacts from PLCs with no RC filter type surge suppression.
RE-PKZ2(220-240V50/60HZ,DC) 063676
RE-PKZ2(24V50/60HZ,DC) 063670
RS-PKZ2 (24V50/60HZ,DC) 063670 Used to electrically operate the PKZ2. Control voltage from external source such as a PLC.

OFF equals RESET.
RS-PKZ2
(110-120V50/60HZ,DC)
063685 Used to electrically operate the PKZ2. Line control sections are galvanically separated. The control section is energized solely from a 24V DC source by a single impulse or by a maintained contact. Suitable for energizing directly from an electronic PLC output.

Upon energizing, the line connection draws its power requirement (700 VA/W for a duration for 30 ms) directly from the line.
RS-PKZ2 (24V50/60HZ,DDC) 063682 Used to electrically operate the PKZ2.