PKZ2 Shunt Trips and Undervoltage Releases

Your authority for all PKZ2 Shunt Trips and Undervoltage Releases, offering expert support and service with all your PKZ2 needs!


Shunt trips are available in three models which cover a wide range of AC and DC voltages. They can be used in combination with R(E)(S)-PKZ2 remote control drives.

  Article # Description Trips the PKZ2 when external
voltage is applied
A-PKZ2-A 063967 Shunt Trip Module

Specify Voltage and AC or DC
24 V DC  
48 V DC
60 V DC
24 V 50 Hz
48 V 50 Hz
24 V 60 Hz
48 V 60 Hz
A-PKZ2-B 063964 Specify Voltage and AC or DC
110 V DC
125 V DC
250 V DC
110 V 50 Hz
127 V 50 Hz
220 V 50 Hz
230 V 50 HZ
240 V 50 Hz
110 V 60 Hz
120 V 60 Hz
208 V 60 Hz
220 V 60 Hz
240 V 60 Hz
A-PKZ2-C 063930 Specify Voltage and AC or DC
380 V 50 Hz
400 V 50 Hz
415 V 50 Hz
440 V 50 Hz,
500 V 50 Hz
480 V 60 Hz
600 V 60 Hz
Can be combined with the motor protector to accomplish Emergency-stop circuitry per IEC/EN 60 204. Can be used in combination with R(E)(S)-PKZ2 remote control drives
  Article # Description Voltage
U-PKZ2(24V50HZ) 055085 Trips the PKZ2 when
external voltage is removed
24V50HZ
U-PKZ2(220V50HZ,240V60HZ) 065685 220V50HZ,
240V60HZ
U-PKZ2(230V50HZ,240V60HZ) 065766 230V50HZ,
240V60HZ
U-PKZ2(400V50HZ,440V60HZ) 065767 400V50HZ,
440V60HZ
 U-PKZ2(24VDC)  014463 For DC 24VDC
U-PKZ2(48VDC) 028701 Trips the PKZ2 when
external voltage is removed
48VDC
U-HI20-PKZ2(*V50HZ) 907537 Trips the PKZ2 when external voltage
is removed. Includes a set of early make
contacts. In the trip position,
both contacts will be closed.
The trip coil can be energized
early by jumpering from the
contact, however
in this move it will not be
possible to combine it with the
 R(E)(S)-PKZ2
remote control drives.
Under voltage Trip Module (for AC)

*V50HZ
U-HI20-PKZ2(110V50HZ,120V60HZ) 063655 110V50HZ,120V60HZ
U-HI20-PKZ2(*V60HZ) 907538 *V60HZ
U-HI20-PKZ2(220V50HZ,240V60HZ) 063656 220V50HZ,240V60HZ
U-HI20-PKZ2(230V50HZ,240V60HZ) 065768 230V50HZ,240V60HZ
U-HI20-PKZ2(24V50/60HZ) 063659 24V50/60HZ
U-HI20-PKZ2(24V50HZ) 063649 24V50HZ)
Has a built in time delay to prevent tripping due to momentary power losses of 200 ms or less. In the trip position, both contacts will be closed. Can be used in combination with the R(E)(S)-PKZ2 remote control drives.
UVHI-PKZ2(120V60HZ) 063664 Drop-off delayed (200ms)
For AC with auxiliary contact
120V60HZ